• RL-Semi 1 Syringe Pump
RL-Semi 1 Syringe Pump

RL-Semi 1 Syringe Pump

RL-Semi 1 Syringe Pump


Technical specification

Applicable Syringe Size :      2ml,5ml,10ml,20ml,30ml,50/60ml

Rate                               :      2ml: 0.01~60ml

                                             5ml: 0.01~150ml

                                            10ml: 0.01~300ml

                                            20ml: 0.01~600ml

                                            30ml: 0.01~900ml

                                           50/60ml: 0.01~2200ml

Bolus Rate & Volume     :   2ml: 0.01~48ml/h       0.10.5ml

                                          5ml: 0.01~120ml/h      0.11ml

                                         10ml: 0.01~240ml/h     0.15ml

                                         20ml: 0.01~480ml/h     0.110ml

                                         30ml: 0.01~720ml/h     0.110ml

                                        50/60ml: 0.01~1500ml/h 0.110ml

FF Rate                        :  2ml: 0.01~60ml

                                        5ml: 0.01~150ml

                                        10ml: 0.01~300ml

                                        20ml: 0.01~600ml

                                        30ml: 0.01~900ml

                                       50/60ml: 0.01~2200ml

KVO Rate & Volume    : Rate: 0.01~5.0ml/h

                                      Volume:

                                                 2ml: 0~0.2ml

                                                 5ml: 0~0.2ml

                                                10ml: 0~0.2ml

                                                20ml: 0~0.5ml

                                                30ml: 0~0.5ml

                                               50/60ml: 0~1ml

Rate Accuracy           :      within ±2%(after calibration)                              

Occlusion Pressure Levels:     13 Levels are available

Alarms Information      :      Injection finish, soon finish, VTBI finished, system stand-by freedom,injection is blocked, syringe falls off, syringe improperly installed, forgotten operation, low battery, battery runs out, abnormal running state, equipment failure, system power down ect.

Power Source            :      Three options for power supply

                                         First: 100~240VAC,50/60Hz;

                                         Second: Inserted Li battery 11.1V, capacity³2600mAh; 8 hours backup time at the rate of 5ml/h for a fully charged battery.

                                        Third: External DC 15V power supply

Drug Library            :       Up to 1000 drugs are provided.

Dimensions             :       301mm(L) * 183mm(W) * 82mm(H)


Inquiry:

CATEGORIES

LATEST NEWS

CONTACT US

Contact: Mr. Jin

Phone: + 86 15951972343

Tel: + 86 15951972343

Email: jin@runlai-medical.com; rl_medical@126.com

Add: ZhangJiaGang City, Jiangsu Province, P.R.China   PC:215600

Leave a message

Facebook

Twitter

LinkedIn

pinterest

Youtube

instagram

+ 86 15951972343

whatsapp

jin@runlai-medical.com; rl_medical@126.com

448473895

Top