• RL-2010 Portable Ventilator
  • RL-2010 Portable Ventilator
  • RL-2010 Portable Ventilator
  • RL-2010 Portable Ventilator
  • RL-2010 Portable Ventilator
  • RL-2010 Portable Ventilator
  • RL-2010 Portable Ventilator
  • RL-2010 Portable Ventilator
  • RL-2010 Portable Ventilator
  • RL-2010 Portable Ventilator
RL-2010 Portable VentilatorRL-2010 Portable VentilatorRL-2010 Portable VentilatorRL-2010 Portable VentilatorRL-2010 Portable VentilatorRL-2010 Portable VentilatorRL-2010 Portable VentilatorRL-2010 Portable VentilatorRL-2010 Portable VentilatorRL-2010 Portable Ventilator

RL-2010 Portable Ventilator

RL-2010 Portable Ventilator

Extraordinary Performance Points

* Pneumatic driven, Electronic control

* Advanced monitoring and alarm systems for patient-related parameters

* Intelligence operating system

* Easy to carry

* Anti-shock, anti-interference and waterproof

* Can be used in emergency department, department of gynaecology and obstetrics, ICU, transport, outdoor aid, per-hospital aid and beside the bed.

* Power Input:

220V (±10%), 50Hz(±2%) or 110V/60Hz              S

* Battery Back-Up:

Internal Rechargeable                                           S

Sealed Lead Acid, 12V                                         (4 hours)

Car Charger                                                          DC 12V

* Screen Size(inch):                                                5.7

* Gas:

O2, Air                                                                 O2 or air

Pipeline input Range                                           208 kPa~600 kPa

* Ventilation Specification:

Breathing Rate                                                   4~100/min

Inspiratory Duration                                            0.2~6s

Tidal Volume(TV)                                               50-1500ml

Oxygen concentration                                       45%~100%

I:E Ratio                                                             4:1 ~ 1:8

Sigh times                                                          1 ~ 5 Every 100 times

* Ventilation Mode:

IPPV                                                                  S

APONT/CAPA                                                   SPONT(S)/CPAP(O)

A/C                                                                    S

SIGH                                                                 S

SIMV                                                                 S

MANUAL                                                          S

* Inspiratory Trigger Sensitivity:

Pressure Trigger                                               -2.0 kPa ~ 0 kPa

* Monitoring:

Tidal volume                                                     S

Ventilation volume                                            S

Breathing rate                                                  S

Ppeak                                                               S

Oxygen concentration                                      O

* Waveform Display:

Pressure-Time                                                 S

* Alarms:

Apnea                                                              S

Vt too high(low)                                               S

Airway Pressure too high                                S

O2 or Air supply failed                                    S

AC power failure                                             S

Battery under voltage                                     S

No tidal Volume                                              S

Note: “S” Standard         “O” Optional            “_” No

PREVIOUS:CPAPNEXT:RL-3020B ICU Ventilator
Inquiry:

CATEGORIES

LATEST NEWS

CONTACT US

Contact: Mr. Jin

Phone: + 86 15951972343

Tel: + 86 15951972343

Email: jin@runlai-medical.com; rl_medical@126.com

Add: ZhangJiaGang City, Jiangsu Province, P.R.China   PC:215600

Leave a message

Facebook

Twitter

LinkedIn

pinterest

Youtube

instagram

+ 86 15951972343

whatsapp

jin@runlai-medical.com; rl_medical@126.com

448473895

Top